Section 302 covers the current ADA Standards for floor or ground surfaces.
Search Results "Water Closet Clear Floor Space"
-
Floor or Ground Surfaces: ADA Standard Section 302
-
4.2.7 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
- Delta Elongated Concealed Trapway Toilet C43906-WH
- Delta Elongated Toilet C43904-WH
-
Surface and Size [§305.2 and §305.3]
Surface and Size [§305.2 and §305.3] Clear floor spaces must meet requirements for ground and floor surfaces, including criteria for firmness, stability, and slip resistance....
- Figure 1009.4.1 Clear Deck Space at Transfer Walls ā Drawing from the U.S. Access Board
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
Outdoor Constructed Features
The proposed rule based the size of the clear ground space at outdoor constructed features on the dimensions for clear floor or ground surfaces in 305.2 of the Architectural Barriers Act...
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided. Exception: Where the walls or partitions cannot support the force specified...
- American Standard Baby Devoro 1.28 gpf FloWise 10 Inch High Round Front Toilet
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
11B-608.2.2.1 Clearance. A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
- Figure 810.3 Bus Shelters ā Drawing from the U.S. Access Board
- American Standard Cadet 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...