The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
Search Results "Water Closet Clear Floor Space"
-
11B-604.9.3 Height
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
Floor Height [1013.4]
If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
III. Handrails and Stanchions
When identifying the clear floor space where a wheelchair or mobility aid user can be accommodated, it is suggested that at least one such area be adjacent or in close proximity to a handrail...
-
11B-809.2.2 Turning space
Exception: Turning space shall not be required in exterior spaces 30 inches (762 mm) maximum in depth or width. [2010 ADAS] Advisory 809.2.2 Turning Space....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Lavatories can be located within the clear floor space (as shown in ADAAG Figure 35)....
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
-
11B-1006.4 Weather shelters
A clear floor or ground space 60 inches (1524 mm) minimum by 96 inches (2438 mm) minimum shall be provided within weather shelters....
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....