Where multiple sinks are provided in a space (e.g., laboratory classrooms), access to at least one or 5% in each such space is generally sufficient....
Search Results "Water Closet Clear Floor Space"
-
Sinks [4.24]
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
- Zurn Z5560 Commercial EcoVantage Elongated Toilet ADA Height
-
11B-806.2.3.1 Personal lift device floor space
In transient lodging facilities, clearance for the use of a personal lift device shall be provided under the bed(s) and adjacent to the clear floor space required by Section 11B-806.2.3....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
4.16.4* GRAB BARS
Grab bars for water closets not located in stalls shall comply with Fig. 29 and 4.26....
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
Re: 604.2 Water Closet Location
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
- Delta Elongated Toilet C43904-WH
- Delta Elongated Concealed Trapway Toilet C43906-WH
-
Are closet doors and pantry doors required to comply?
Doors serving walk-in closets or pantries must comply....
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-813.2.1.2 Clearance
Floor or ground surfaces of clearances shall comply with Section 11B-302. Changes in level are not permitted....
-
11B-813.2.1.2 Clearance
Floor or ground surfaces of clearances shall comply with Section 11B-302. Changes in level are not permitted....
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
R404.7 Maneuvering Space
R404.7 Maneuvering Space. Where a clear space is confined on all or part of three sides, additional maneuvering space shall be provided in accordance with R404.7.1 and R404.7.2....