(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
4.15.5(1)
- TOTO® CT705ELN Commercial Flushometer High Efficiency Toilet
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
11B-608.2.2.1 Clearance. A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
1015.2 Clear Ground Space
This section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for either a forward or parallel approach to be provided at each distinct viewing location, and...
-
4.5.3 Slope
The slope of the clear floor or ground space for trash, recycling, and other essential containers shall not exceed 1:48 (2 percent) in any direction. Exception....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
- Zurn Z5560 Commercial EcoVantage Elongated Toilet ADA Height
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided. Exception: Where the walls or partitions cannot support the force specified...
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
General: ADA Standard Section 609.1
Section 609.1 of the ADA Standards covers information in the current ADA Standards for grab bars in toilet facilities and bathing facilities.
-
Plumbing Fixtures and Accessories: ADA Standard Section 213.3
Section 213.3 covers scoping requirements in the current ADA Standards for plumbing fixtures and accessories.
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609.
-