Cross Slope—The percentage of rise to length when measuring the trail tread from edge to edge perpendicular to the direction of travel....
Search Results "Measuring Technique"
Commonly Searched Documents
-
Cross Slope
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Drinking Fountain Water Flow Tool
Drinking Fountain Water Flow Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring drinking fountain water flow....
-
1.1.2 Walks
Measure walks and other non - ramp pedestrian surfaces for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with 1.1.3...
-
1. Job-Related
qualification standard, test or other selection criterion operates to screen out an individual with a disability, or a class of such individuals on the basis of disability, it must be a legitimate measure...
-
Truncated Domes
The proposed rule specified that the truncated domes have a diameter of 0.9 inch, measured at the base....
-
SUMMARY OF THE 19-INCH RECOMMENDATION
Note that height measurement, as defined by the tables and chairs subcommittee, represents the highest point of the transfer surface, inclusive of bolsters, when measuring to the top of...
-
3.3.3 Clear Floor Width
Neither the DfT or DETR studies collected data on occupied width but did measure the unoccupied device width....
-
1 - Design and drawing
In addition, current practice for architectural and construction engineering drawings establish ambiguity and the potential for accumulated measurement error....
- Access-Able Designs Wall Mounted Shower Transfer Bench SH-400
- Access-Able Designs Adult Dressing Bench D-101-42
- Access-Able Designs Rear Mount Tub Transfer Bench w/o Legs SH-414
-
TABLE OF CONTENTS
Passenger Drop-off Locations Accessible Routes Ramps Protruding Objects Building Entrance Lifts and Elevators Tools for Surveys Tools and Documentation Completing Measurements...
-
12.1 Q...How is the individual building test performed for additional stories, to determine if those stories must also be treated as ground floors?
For purposes of determining whether a non-elevator building has more than one ground floor, the point of measurement for additional ground floors, after the first ground floor has been established...
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
REFERENCES
Revised ANSI standard for measurement of hearing instrument performance. The Hearing Journal, 49(10), 49‒57. Preves, D. A. (l994)....
- Access-Able Designs Shower Transfer Bench SH-420-2SDL
- Doorbell Factory Small Rectangle Stainless Steel Doorbell
- Boolee Voting Booth
-
M301.2.1, M302.2.1 Transfer Height
M301.2.1, M302.2.1 Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25 inches....