Kitchen countertops shall comply with this section and shall be provided with the following:
Search Results "Residential Structure"
-
1133A.4 Countertops
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm). Section 1126A.3...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
11B-1002.4.3 Gaps
Exception: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
1002.4.3 Gaps
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
1002.4.3 Gaps
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
11B-809.10.6.1 Size
Triennial Code Cycle": "Amendment removes the reference to Section 11B-608.1 for accessible transfer showers and replaces the reference with specific shower requirements applicable to residential...
-
4.1.6(2)
(2) Alterations to an Area Containing a Primary Function: In addition to the requirements of 4.1.6(1), an alteration that affects or could affect the usability of or access to an...
-
Toilet Stalls [4.17]
Toilet Stalls [4.17] The standard stall in section 4.17 is wheelchair accessible. Since wheelchair accessible or "standard" stalls are designed to accommodate the broadest range...
-
10.3.2(3)
(3) Where technical infeasability [sic] in existing stations requires the accessible route to lead from the public way to a paid area of the transit system, an accessible fare...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
Slope and Rise [4.8.2]
Slope represents the proportion of vertical rise to horizontal length and can be represented as a ratio (as in ADAAG), percentage, pitch or in...
-
Common Questions (Alterations and Additions)
Common Questions
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to...
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor. Where towel bars are provided they shall be...
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm)...
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.