Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
Search Results "Residential Structure"
-
1132A.8 Hand-activated door hardware
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
3104.2 Separate structures
Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures....
-
11B-216.5.1 Parking spaces
In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required....
-
3104.2 Separate structures
Exceptions: … [DSA-AC and HCD 1-AC] For purposes of accessibility in residential facilities as required by Chapters 11A and 11B, structurally connected buildings, buildings...
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
Altered Elements on an Accessible Route
A third exception has been added in the final rule for residential facilities (202.3, Exception 3)....
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 3
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 3 Subject: "Program Accessibility" Requirements Policy Interpretation: A recipient is not required to make structural...
-
11B-809.11 Washing machines and clothes dryers
Where washing machines and clothes dryers are provided in residential dwelling units with adaptable features, one of each type shall be provided....
-
11B-206.2.3 Multi-story buildings and facilities
In residential facilities, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with Sections 11B-809.2...
-
607.4 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
607.4 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...