However, the Board has revised the specified depth in residential dwelling units where lavatories are permitted to overlap the space aside water closets....
Search Results "Residential Structure"
Commonly Searched Documents
-
Water Closet Clear Floor Space in Toilet Compartments
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
11B-233.3.1.2.3 Ground floors above grade
Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable....
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4. Spaces and elements within employee workstations shall only be required to comply with Sections...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
Elevators: ADA Standard Section 206.6
Section 206.6 covers scoping requirements in the most current ADA Standards for accessible routes to elevators.
-
11B-233.3.4 Alterations
Exception: Where compliance with Sections 11B-809.2, 11B-809.3, or 11B-809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential...
-
§8.23 Alterations of existing housing facilities.
[See subsections ...]
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation, and carbon monoxide detection...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
1132A.4 Level floor or landing
1132A.4 Level floor or landing. See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors...
-
1132A.5 Maneuvering clearances at doors
1132A.5 Maneuvering clearances at doors.
-
1133A.4 Countertops
1133A.4 Countertops. Kitchen countertops shall comply with this section and shall be provided with the following:
-
1132A.8.1 Lever-type hardware
1132A.8.1 Lever-type hardware. The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the...
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors. Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push...
-
1133A.1 General
1133A.1 General. Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
-
1132A.4.1, Item 2
2. Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal...