Water closets required by Section 11B-809.10 shall comply with this section.
Search Results "Residential Structure"
Commonly Searched Documents
-
11B-809.10.7 Water closets
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.7 Accessible routes
An accessible route shall be provided complying with Section 11B-809.7. The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and...
-
608.3 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
608.3 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
Users and Needs
Many of the facilities reviewed were healthcare and residential facilities specifically designed for older adults....
-
11B-233.3.4 Alterations
Exception: Where compliance with Sections 11B-809.2,11B-809.3, or 11B-809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential...
-
Altered Elements on an Accessible Route
A third exception has been added in the final rule for residential facilities (202.3, Exception 3)....
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
608.3 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
11B-233.3.4 Alterations
dwelling unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with Sections 11B-809.2 through 11B-809.4 or Chapter 11A, Division IV...
-
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 3
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 3 Subject: "Program Accessibility" Requirements Policy Interpretation: A recipient is not required to make structural...
-
604.3.2 Overlap
[ECTCR UFAS 4.16.2, Fig. 28, 4.34.5.2(1), Fig. 47(a)] EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum...
-
202.5 Alterations to Qualified Historic Buildings and Facilities
Alterations to a qualified historic building or facility shall comply with 202.3 and 202.4. Alterations to buildings or facilities that are eligible for listing in the National...
-
202.5 Alterations to Qualified Historic Buildings and Facilities
202.5 Alterations to Qualified Historic Buildings and Facilities. Alterations to a qualified historic building or facility shall comply with 202.3 and 202.4 to the maximum extent...
-
4.1.6(3)(h) Dressing Rooms
(h) Dressing Rooms: In alterations where technical infeasibility can be demonstrated, one dressing room for each sex on each level shall be made accessible. Where only unisex...
-
What requirements of the standards apply in an alteration?
Application of the standards in an alteration is determined by the scope of work and whether it involves areas containing a primary function. Altered elements or spaces must comply...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....