When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
Search Results "Residential Structure"
Commonly Searched Documents
-
11B-809.1 General
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
-
§ 35.151(d) Scope of coverage
The proposed standards apply to fixed or built-in elements of buildings, structures, site improvements, and pedestrian routes or vehicular ways located on a site....
-
§ 35.151(d) Scope of coverage.
The 1991 Standards and the 2010 Standards apply to fixed or built-in elements of buildings, structures, site improvements, and pedestrian routes or vehicular ways located on a site....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
Appendix to May 23, 2014 Document
Section 35.151(a)(2) Exception for structural impracticability 2010 Standards at Section 35.151 without Section 35.151(a)(2) and (b) (see below) and HUD’s Section 504 regulation...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
233.1 General
Section 233 outlines the requirements for residential facilities subject to Texas Government Code, Chapter 469....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
VALUATION THRESHOLD
. ◼ 2016 Valuation Threshold for Alterations, Structural Repairs or Additions to Existing Buildings In accordance with the 2013 California Building Code Chapter 2 definition...
-
VALUATION THRESHOLD
to 2000 are available on the Division of the State Architect web site at: http://www.dgs.ca.gov/dsa/Programs/progAccess/threshold.aspx◼ 2016 Valuation Threshold for Alterations, Structural...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-233.3.4 Alterations
Clarifies in the exception the technical requirements for accessible residential dwelling units when alterations are made to existing public housing facilities are technically infeasible...
-
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...