3. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by...
Search Results "Residential Structure"
Commonly Searched Documents
-
1133A.2, Item 3
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp,...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp,...
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit. The accessible route shall pass through the primary entry door, and shall connect with all...
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including...
-
1131A.1 Changes in level not exceeding ½ inch
Abrupt changes in level along any accessible route shall not exceed ½ inch (12.7 mm). When changes in level do occur, they shall be beveled with a slope no greater than 1 unit...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
Homeless Shelters, Group Homes, and Similar Social Service Establishments
Section 233 of the 2010 Standards includes specific scoping and technical provisions that apply to new construction and alteration of residential facilities....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
The term bathing rooms and fixtures is used in this section to denote the various configurations of sanitary facilities that are designed in residential units....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower...