Search Results "Grab Bar Height"
Commonly Searched Documents
- 606.3 Lavatory Height
- Smith System Trespa Planner Science Table 30″ Deep 11288
-
4.8.5(5)
(5) Top of handrail gripping surfaces shall be mounted between 34 in and 38 in (865 mm and 965 mm) above ramp surfaces.
-
4.9.4(5)
(5) Top of handrail gripping surface shall be mounted between 34 in and 38 in (865 mm and 965 mm) above stair nosings.
-
The Brewer Company, LLC
for adjustable height transfer surfaces....
-
4.1.2 Surface Design of Examination Tables and Chairs
Thus, contouring must be addressed in considering minimum height standards for accessibility of transfer surfaces (Section 5.1.4)....
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
- Access Board: Standard Roll In Shower Stalls
-
Bed Height Fact Sheet
Hotels need to adopt the recommended bed height range so individuals can safely transfer to and from the bed....
-
4.30.6 Mounting Location and Height
4.30.6 Mounting Location and Height. Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Where mirrors or towel bars are provided, no less than one of each shall comply with this section....
-
§ 38.113(d)(2) Exception
New cars operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
Handrails
...are there handrails on both sides of the stair at a uniform height of 34"-38" above the front edge of the step?...
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
- Delta Two Handle Blade Bar/Prep Faucet 2171LF-WBHHDF
- Mockett TLRAL27 Roma Series Adjustable Table Leg
-
Chapter 4: Implications for standards and design
[See subsections ...]
- Diversified Woodcrafts 9010 ARM Lab Table Accessory
-
Conclusions
The results of the expert review of the literature highlight the need for future studies particularly as it relates to how environmental factors such as height and gap distances, use of...
-
Parallel Approach to Kitchen Sinks
This exception also applies to wet bars....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
§ 38.73(d)(1) Requirements
shall be coordinated with the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall be no greater than 3 inches and the height...
-
National Council on Independent Living
National Council on Independent Living MDE Minority Paper for a 17 inch low Transfer Surface Height Submitted to the U.S....