Vertical clearance at parking spaces, access aisles and vehicular routes. 11B-502.5 Location, number and dimensions of passenger drop-off zones...
Search Results "PLZ: Passenger Loading Zone"
-
Parking
-
503 Passenger Loading Zones
-
Parking
Vertical clearance at parking spaces, access aisles and vehicular routes. 11B-502.5 Location, number and dimensions of passenger drop-off zones...
-
503.1 General
Passenger loading zones shall comply with 503....
-
503.2 Vehicle Pull-Up Space
Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) wide minimum and 20 feet (6100 mm) long minimum....
-
4.3.2(1)
(1) At least one accessible route within the boundary of the site shall be provided from public transportation stops, accessible parking, and accessible passenger loading zones, and public...
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3.1 Width
Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum.
-
503.3.2 Length
Access aisles shall extend the full length of the vehicle pull-up spaces they serve.
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level are...
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
4.6 PARKING AND PASSENGER LOADING ZONES
-
4.6 Parking and Passenger Loading Zones
-
4.6.1 MINIMUM NUMBER
Passenger loading zones required to be accessible by 4.1 shall comply with 4.6.5 and 4.6.6....
-
4.6.1 Minimum Number
Passenger loading zones required to be accessible by 4.1 shall comply with 4.6.5 and 4.6.6....
-
4.6.5 PASSENGER LOADING ZONES
Passenger loading zones shall provide an access aisle at least 60 in (1525 mm) wide and 20 ft (6 m) long adjacent and parallel to the vehicle pull-up space (see Fig. 10)....
-
4.6.5* Vertical Clearance
Provide minimum vertical clearance of 114 in (2895 mm) at accessible passenger loading zones and along at least one vehicle access route to such areas from site entrance(s) and exit(s)....
-
4.6.6 VERTICAL CLEARANCE
Provide minimum vertical clearances of 114 in at accessible passenger loading zones and along vehicle access routes to such areas from site entrances....
-
4.6.6 Passenger Loading Zones
Passenger loading zones shall provide an access aisle at least 60 in (1525 mm) wide and 20 ft (240 in)(6100 mm) long adjacent and parallel to the vehicle pull-up space (see Fig. 10)....
-
Parking and Passenger Loading Zones [4.6]
Accessible parking and passenger loading zones require aisles alongside parking and pull-up spaces so that persons using mobility aids can transfer and maneuver to and from vehicles....
-
Valet Parking
Where only valet parking is provided, an accessible passenger loading zone is required....
-
Vertical Clearance [4.6.5]
(A higher clearance (114 inches) is required for passenger loading zones to accommodate other types of transit vehicles, including vans used for shuttle service)....
-
Guidelines for Requirement 2
A number of proposals for revisions were submitted on the final Guidelines for parking and passenger loading zones. Response. The Department has not adopted any of these proposals....
-
Passenger Loading Zones [4.6.6]
Where zones are specifically designed for passenger loading and unloading, at least one on a site must be accessible....