However, these fixed heights tables do not allow for independent transfer of patients who use wheeled mobility devices (WMD)....
Search Results "ACA: Patient Protection and Affordable Care Act"
Commonly Searched Documents
-
How to Measure Transfer Surface Height
-
§ 38.95(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off.
-
§ 38.95(b)(5) Platform barriers
(5) Platform barriers. The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the lift during its operation....
-
"Lead On" - Americans with Disabilities Act 23 years later
Requires the Registered User plan or above. Login!
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use....
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1)....
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs....
-
36 CFR Part 1193 Telecommunications Act (Section 255) Accessibility Guidelines
ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1193 [Docket No. 97–1] RIN 3014–AA19 Telecommunications Act Accessibility Guidelines AGENCY: Architectural...
- Defining and Delivering Disability-Competent Care - The Care Coordination Relationship
-
Detention Facilities and Correctional Facilities: ADA Standard Section 232
Section 232 covers scoping requirements in the current ADA Standards for detention facilities and correctional facilities.
-
General: ADA Standard Section 233.1
Section 233 of the ADA Standards covers information in the current ADA Standards on scoping requirements for residential facilities.
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
Some imaging systems already use overhead lifts to assist patients. Overhead lifts are not feasible in the MR exam room due to the magnetic fields....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
MDE Advisory Committee Report, 75-82, available at https://www.access-board.gov/guidelines-and-standards/health-care/about-this-rulemaking/advisory-committee-final-report. ...
-
ACCESS NOW, INC. v. AMBULATORY SURGERY CENTER GROUP, LTD.
UNITED STATES DISTRICT COURT FOR THE SOUTHERN DISTRICT OF FLORIDA MIAMI DIVISION CASE NO. 99-109-CIV-GARBER ACCESS NOW, INC., et....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
Preamble Discussion: The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients...
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
Q15: Does the Amendments Act require the Department to revise or create new Section 504 regulations to implement the Amendments Act?
The Amendments Act does not require the Department to revise its existing Section 504 regulation or to create new regulatory provisions....
-
Social Policy
Policies that prevent people from having access to comprehensive health care can be a huge barrier....
-
Communication Access
guidelines noted in Section K, L, M and strive to ensure notes, handouts, brochures, consent forms, health education materials, instructions and other materials where needed to ensure patient...
- Brewer Access™ High-Low Exam Table
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.