M305.2.1 Location (Section-by-Section Analysis)
MDE Advisory Committee Report, 86, available at https://www.access-board.gov/guidelines-and-standards/health-care/about-this-rulemaking/advisory-committee-final-report....
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent patient...
-
36 CFR Part 1193 Telecommunications Act (Section 255) Accessibility Guidelines
ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1193 [Docket No. 97–1] RIN 3014–AA19 Telecommunications Act Accessibility Guidelines AGENCY: Architectural...
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use....
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
How to Measure Transfer Surface Height
However, these fixed heights tables do not allow for independent transfer of patients who use wheeled mobility devices (WMD)....
-
General: ADA Standard Section 233.1
Section 233 of the ADA Standards covers information in the current ADA Standards on scoping requirements for residential facilities.
- President Obama Speaks at the 25th Anniversary of the ADA
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs....
-
22. Q: How do I make my child care center's building, playground, and parking lot accessible to people with disabilities?
Q: How do I make my child care center's building, playground, and parking lot accessible to people with disabilities?...
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1)....
-
Q15: Does the Amendments Act require the Department to revise or create new Section 504 regulations to implement the Amendments Act?
The Amendments Act does not require the Department to revise its existing Section 504 regulation or to create new regulatory provisions....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
Some imaging systems already use overhead lifts to assist patients. Overhead lifts are not feasible in the MR exam room due to the magnetic fields....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
MDE Advisory Committee Report, 75-82, available at https://www.access-board.gov/guidelines-and-standards/health-care/about-this-rulemaking/advisory-committee-final-report. ...
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
Preamble Discussion: The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients...
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
"Lead On" - Americans with Disabilities Act 23 years later
Requires the Registered User plan or above. Login!
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface.
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...