Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be...
Search Results "Elevator Hall Call Button"
Commonly Searched Documents
-
11B-411.2.3.2 Car designation signs
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
Additional clarification requested
Please add 2010 ADA cite reference
-
response to feedback
Take a look now and see if there is anything else you would suggest. Thanks for the feedback.
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
Relationship Between Primary and Secondary PSAPs
Primary PSAPs (9-1-1 answering points) often transfer calls to secondary PSAPs (such as fire or emergency medical services) if they do not dispatch those services directly from the primary...
-
216.7 Elevators
216.7 Elevators....
-
Connected Elevated Components
Connected Elevated Components When transfer systems are used, an elevated play component may connect to other elevated play components, providing an innovative, accessible route....
-
Common Questions (Elevators and Platform Lifts)
Common Questions
-
Designations and Indicators of Car Controls: ADA Standard Section 408.4.7
Section 408.4.7 covers the current ADA Standards for designations and indicators of car controls in limited-use/limited-application elevators.
-
11B-408.4.8 Emergency communications
Car emergency signaling devices complying with Section 11B-407.4.9 shall be provided.
-
11B-408.4.7 Designations and indicators of car controls
Designations and indicators of car controls shall comply with Section 11B-407.4.7.
-
Frequency: ADA Standard Section 407.4.8.2.3
Section 407.4.8.2.3 covers the current ADA Standards for the frequency of audible elevator car indicators.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
1008.2.5.2 Elevated
1008.2.5.2 Elevated. The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
F216.7 Elevators
Where existing elevators do not comply with 407, elevators complying with 407 shall be clearly identified with the International Symbol of Accessibility complying with 703.7.2.1....
-
216.7 Elevators
Where existing elevators do not comply with 407, elevators complying with 407 shall be clearly identified with the International Symbol of Accessibility complying with 703.7.2.1....
-
Symmetry Elevating Solutions Limited Use/Limited Application (LU/LA) Elevator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
409 Private Residence Elevators
[See subsections ...]