(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
Search Results "Automatic Door"
Commonly Searched Documents
-
A4.13.11(3) Application of force
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
Controls [4.34.4]
Controls [4.34.4] Controls for user activation must: be automatic or operable with one hand operate without tight grasping, pinching, or twisting of the wrist...
-
Communication Access at Doors [§806.3.2, §809.5.5]
Communication Access at Doors [§806.3.2, §806.3.2] ETA Editor's Note This section title contains a typo, as it duplicates section number "806.3.2."...
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
D3. Door Hardware
Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?...
-
Tactile Symbols: ADA Standard Section 707.6.3.2
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value...
-
Braille Instructions: ADA Standard Section 707.8
Braille instructions for initiating the speech mode shall be provided. Braille shall comply with 703.3.
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value...
-
11B-707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces. Visual contrast shall be either...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
- Hager Companies 4.75” Square ADA Actuator 2-659-0305
- Hager Companies 6” Round ADA Actuator 2-659-0307
- Hager Companies 6” Round ADA Actuator 2-659-0304
- Hager Companies 4.75” Round ADA Actuator 2-659-0306
- Hager Companies 4.75” Square ADA Actuator 2-659-0308
- Hager Companies 6” Round ADA Actuator 2-659-0303