Where display screens are mounted tipped away from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices...
Search Results "Automatic Door"
-
11B.707.7.1.3 Horizontally mounted display screen
-
11B.707.7.1.1 Vertically mounted display screen
Where display screens are mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more...
-
11B-707.6.3 Function keys
Function keys shall comply with Section 11B-707.6.3.
-
2.2.6 Door Use
2.2.6 Door Use Our study of door use had three main objectives all intended to provide groundwork for future studies aimed at design guidelines and standards that would make doors more...
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
- Norton Surface Mounted 5700 Series Low Energy Door Operator
-
Door and Gate Hardware [§404.2.7]
Door and Gate Hardware [§404.2.7] Door and gate hardware must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate...
-
304.4 Door Swing
304.4 Door Swing. Doors shall be permitted to swing into turning spaces....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
1010.1.4.1 Revolving doors
Revolving doors shall comply with the following: 7. Revolving doors shall not be part of an accessible route required by Section 1009 and Chapter 11A or 11B....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in...
-
Door Hardware
A few commenters requested that lever hardware be required on doors throughout dwelling units, not only at the entry door to the dwelling unit. Response....
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and 0-16...