5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces. Transfer supports for imaging equipment should be 28 inches minimum in length and...
Search Results "Side Entry"
Commonly Searched Documents
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
-
i. Medical examination and treatment tables and chairs
i. Medical examination and treatment tables and chairs Healthcare providers use examination and treatment tables and chairs for many different types of medical and dental...
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
position, and diagnostic equipment used by patients in a seated position: At least one transfer support would be provided on the side of the transfer surface that is 15 inches...
-
1008.4.4 Entry Points and Seats
1008.4.4 Entry Points and Seats....
-
1002.5.3 Transfer Entry
1002.5.3 Transfer Entry....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1132A.1 Primary entry doors and required exit doors
1132A.1 Primary entry doors and required exit doors. The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
- San Francisco: Accessible Business Entrance Program
-
Manual Doors and Gates [§404.2]
Manual Doors and Gates [§404.2]
-
Reach Ranges
The 1991 Standards set the maximum height for side reach at 54 inches above the floor....
-
M305.2.2 Length (Section-by-Section Analysis)
The Board restructured the Committee’s recommendations to fit within the end and side transfer supports discussed above....
- Door King Inc. 1803 Telephone Entry System
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
Tips for Weighing People Using an Accessible Scale
By June Isaacson Kailes, Associate Director Harris Family Center for Disability and Health Policy Western University of Health Sciences, Pomona, California Update -...
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
- Bradley Security Grab Bars SA70 Series
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids...