M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Head and Back Support (M301.3.3 and M302.3.3)
Where diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position can be adjusted to reclined positions...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented along the long dimension of the surface on which patients are positioned in the supine, prone, or side-lying...
-
Entry Points and Seats
Entry Points and Seats Entry points and seats are features of play components where individuals would transfer, sit, or gain access....
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view the information shown in Fig. 4, 5, and...
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view information shown in Fig. 4, 5, and 6 in other...
-
2. c. REACH RANGES
Figure 18 (high forward reach range), and Figure 19 (side reach range) illustrate reach ranges accessible to wheelchair users or people with limited mobility....
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum....
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level landings each side...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level landings each side...
- Guldmann Excellent Ramp System
-
A4.17.3 Size and Arrangement
A standard stall provides a clear space on one side of the water closet to enable persons who use wheelchairs to perform a side or diagonal transfer from the wheelchair to the water closet...
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301....
-
M301.2.3 Size
The size of transfer surfaces shall be measured from center points of their opposing sides....
-
A4.27.3 Height
Fig. A8 further illustrates mandatory and advisory control mounting height provisions for typical equipment. Electrical receptacles installed to serve individual...
-
3.5.3 Signs in General
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS.
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....