5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface...
Search Results "Side Entry"
Commonly Searched Documents
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment. Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface. The...
- Inclusion Solutions BigBell™ Flex Alert System
-
Adjustable Height Range Considered
Many types of diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position currently provide adjustable...
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer supports shall be mounted on both sides of the transfer surface and must be movable or removable so they can be out of way of transfer....
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
- Brewer Access™ High-Low Exam Table 700
-
5.4.1 Transfer Support Location for M301 and M302
NPRM Preamble Discussion: The transfer support would be located on the side of the transfer surface that is opposite the transfer side (M301.2.3 and M302.2.3) similar to the provisions in...
-
6. Transfer Surface Height
6. Transfer Surface Height 6.3 Diagnostic Imaging Equipment Refer to the Rationale found in Section 5.3 for M301.2.1 and to Section 4.3. For many types of imaging equipment it...
-
M305.5 Head and Back Support (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients in the supine, prone, or side-lying position and the seated position that can be adjusted to a reclined position to...
- ABC Chicago: Small Business Accessibility with BigBell
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
- Bradley Grab Bars 1 1/2" with Exposed Mounting 817
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
205 and 309 Operable Parts
205 and 309 Operable Parts Section 4.1.3, and more specifically sections 4.1.3(13), 4.27.3, and 4.27.4 of the 1991 Standards, require operable parts on accessible elements, along...
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment. The transfer or positioning support should be oriented horizontally on imaging equipment with transfer...