Attractive Compact double roll, side-by-side coreless bathroom tissue dispensing system provides up to six times the capacity of single standard 2-ply rolls while maintaining your professional...
Search Results "Side Entry"
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56798
-
Side guard protocol
Side guard protocol: From initial setup, two side guards adjusted 6” (15.2 cm) higher than the subject’s WMD seat were attached, and subjects were asked to perform a level height transfer...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum....
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
M301.3.1 Transfer Supports
Transfer surfaces required by M301.2 shall provide transfer supports and shall comply with M305.2.
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M301.3 Supports
Transfer supports, leg supports, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M301.3 Supports (Section-by-Section Analysis)
This is an introductory section. An editorial change was made to this section as a result of the change in M301.3.2, described below, to replace the word “stirrups” with the term...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded...
-
M301.3 Supports
Transfer supports, stirrups, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
- Brewer Assist Power Procedure Table™
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Figure 406.6 Diagonal or Corner Type Curb Ramps – Drawing from the U.S. Access Board
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56797