Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-703.4.2 Location
-
EXHIBIT B
EXHIBIT B The average anthropometric dimensions employed shall be: (1) average eye height for a person sitting in a wheelchair is 47.45"; (2) horizontal distance from the eye of an average...
-
T-Shaped Space: ADA Standard Section 304.3.2
Section 304.3.2 covers the current ADA Standards for t-shaped turning space.
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Width at Turn: ADA Standard Section 403.5.2
Section 403.5.2 covers the current ADA Standards for the clear width at a turn on walking surfaces that are part of an accessible route.
-
2. Shoulder Breadth
As such, the width dimension should be based on the higher end of the sample distribution to provide a sufficient base of support for as large a proportion of the user population as possible...
- HEWI Panic Bar EN 1125
-
11B-304.3.2 T-Shaped space
The turning space shall be a T-shaped space within a 60 inch (1524 mm) square minimum with arms and base 36 inches (914 mm) wide minimum....
-
11B-809.10.6.1 Size
by 60 inches (1524 mm) wide minimum with an entrance opening 60 inches (1524 mm) minimum....
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
11B-403.5.1 Clear width
by segments that are 48 inches (1219 mm) long minimum and 36 inches (914 mm) wide minimum....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for parallel...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
B. Slopes
.: in the direction of travel) not more than 1:20 (critical dimension of 1 1/4" or less)?...
-
What is an Accessible Seat and Who Can Use One?
Accessible seats are spaces specifically designed for wheelchairs and include features such as an accessible approach, location at grade, clear floor space, and larger dimensions....
-
The Purpose of FSORAG and FSTAG
The building blocks for accessible design are based mostly on wheelchair dimensions, clear space, maneuvering room, and reach ranges found in ABAAS because the dimensions, multiple moving...
-
Size: ADA Standard Section 305.3
Section 305.3 covers the current ADA Standards for the required size of compliant clear floor or ground space.