Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Minimum Dimension"
-
11B-705.1.1.2 Dome spacing
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for parallel...
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for parallel...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Size: ADA Standard Section 305.3
Section 305.3 covers the current ADA Standards for the required size of compliant clear floor or ground space.
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-407.4.7.2 Keypads
The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1 _|Braille Dimensions|_....
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel....
-
Chapter 6: Plumbing Elements and Facilities
Alternate specifications are provided for plumbing elements designed for children’s use as exceptions to requirements based on adult dimensions....
-
1. Measuring Tape
You will generally not need to measure dimensions in increments of less than ¼ inch....
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
Rationale for the Recommendation The Committee decided to follow the recommended 1 1/2inch proposal but included a 3-inch dimension to accommodate movement of the support....
-
Openings in Beach Access Routes
Place elongated openings more than a quarter of an inch wide with the long dimension perpendicular or diagonal to the primary direction of travel (see figure 44)....
-
Openings in Outdoor Recreation Access Route Surfaces
Place elongated openings that are more than a quarter of an inch wide with the long dimension perpendicular or diagonal to the primary direction of travel (figure 44)....
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
It references dimensions of clearance height and depth to the forward-most point on the person or mobility device (e.g., toe, footrest)....
-
Knee Clearance: Clearance as Measured from Dorsal Foot Point - Manual Wheelchair
It references dimensions of clearance height and depth to the dorsal foot point on a person (e.g., top of ankle)....
-
1.2.1
1.2.1 Use the plus - or - minus symbol (±) after a dimension when it must be made clear what the expected tolerance is. This should be coordinated with the specification requirements....
-
11B-407.4.7.2 Keypads
The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1 _|Braille Dimensions|_....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.