Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
Search Results "Maximum Dimension"
Commonly Searched Documents
-
Back Wall: ADA Standard Section 607.4.1.1
-
Seeger et al.
Both unoccupied and occupied dimensions of device width and length were measured as well as a set of other basic dimensions....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
Technical Requirements
Are the specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.)....
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush....
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush....
-
Technical Requirements
The specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.). ...
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Dimensions....
-
Accessibility - Flatness and Lippage
Mortar setting beds for concrete pavers and paving slabs Joint width between paving units with chamfers (See Figure I) Maximum 3/8 in. (10 rom) - The surface of the mortared joint...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
407.2.1.2 Size
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
T102.1 Calculation of Percentages
Where the determination of the required size or dimension of an element involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
Technical Requirements
Technical Requirements—Specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.)....
-
Thresholds: ADA Standard Section 608.7
Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...