Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309....
Search Results "Maximum Dimension"
-
409.2 Call Buttons
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
11B-308.2.2 Obstructed high reach
The high forward reach shall be 48 inches (1219 mm) maximum where the reach depth is 20 inches (508 mm) maximum....
-
11B-308.2.2 Obstructed high reach
The high forward reach shall be 48 inches (1219 mm) maximum where the reach depth is 20 inches (508 mm) maximum....
-
Outdoor Constructed Features
The proposed rule based the size of the clear ground space at outdoor constructed features on the dimensions for clear floor or ground surfaces in 305.2 of the Architectural Barriers Act...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
Rectangular Seats: ADA Standard Section 610.3.1
Section 610.3.1 covers the current ADA Standards for rectangular shower compartment seats.
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
Non-compliant bathtub seat depth
The depth of the seat exceeds the 16" maximum at a depth of 21" (2010 ADA Standards section 610.2). ...
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
Technical Requirements
Are the specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.)....
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush....
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush....
-
Technical Requirements
The specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.). ...
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
Seeger et al.
Both unoccupied and occupied dimensions of device width and length were measured as well as a set of other basic dimensions....
-
304 Turning Space
Comments urged that the minimum dimensions for turning space be increased to better accommodate scooters and motorized wheelchairs....
-
407.2.1.2 Size
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
T102.1 Calculation of Percentages
Where the determination of the required size or dimension of an element involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
Technical Requirements
Technical Requirements—Specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.)....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...