Alterations When a public entity chooses to alter any of its facilities, the elements and spaces being altered must comply with the 2010 Standards....
Search Results "Alteration"
-
Alterations
-
§35.151 New construction and alterations
§35.151 New construction and alterations....
-
Required Compliance [§210]
Alterations In alterations, stairs between levels that are connected by an accessible route (e.g., ramp or elevator) are not required to meet the Standards, but handrails must comply...
-
§35.151(a)
(a) Design and construction. Each facility or part of a facility constructed by, on behalf of, or for the use of a public entity shall be designed and constructed in such manner that...
-
§35.151(b)
(b) Alteration....
-
§35.151(c)
Design, construction, or alteration of facilities in conformance with the Uniform Federal Accessibility Standards (UFAS) (Appendix A to 41 CFR Part 101-19.6) or with the Americans with Disabilities...
-
Handrails [§504.6, §505]
Handrails [§504.6, §505] Handrails are required on both sides of stairs and must be continuous within the full length of each stair flight. Inside handrails on switchback or...
-
§35.151(d)
(d) Alterations: Historic properties....
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects. The...
-
New construction and alteration requirements
New construction and alteration requirements....
-
5.4 Dining Areas
In alterations, accessibility to raised or sunken dining areas, or to all parts of outdoor seating areas is not required provided that the same services and decor are provided in an accessible...
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
Alterations to Accessible Units, Sleeping Rooms, and Suites [9.1.5]
Alterations to Accessible Units, Sleeping Rooms, and Suites [9.1.5] The minimum number of guest rooms required to be accessible in an alteration is based on the total number of guest...
-
505.10 Handrail Extensions
In alterations, full extensions of handrails shall not be required where such extensions would be hazardous due to plan configuration....
-
Multi-Story Buildings and Facilities: ADA Standard Section 206.2.3
Section 206.2.3 covers the scoping requirements in the most current ADA Standards for accessible routes within multi-story buildings and facilities
-
Stairs and Escalators in Existing Buildings: ADA Standard Section 206.2.3.1
Section 206.2.3.1 covers the scoping requirements for accessible routes between stairs and escalators in existing buildings.
-
Restaurants and Cafeterias: ADA Standard Section 206.2.5
Section 206.2.5 covers scoping requirements in the most current ADA Standards for accessible routes in restaurants and cafeterias
-
406.4 Landings
[ECTCR UFAS 4.7.5] EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12....
-
Entrances: ADA Standard Section 206.4
Section 206.4 covers scoping requirements in the most current ADA Standards for entrances on accessible routes.
-
Existing Elevators: ADA Standard Section 206.6.1
Section 206.6.1 covers scoping requirements in the most current ADA Standards for accessible routes existing elevators.
-
General: ADA Standard Section 210.1
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 213.2
Section 213.2 covers scoping requirements in the current ADA Standards for toilet rooms and bathing rooms.
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.