(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches.
Search Results "Alteration"
-
4.1.6(3)(a)(i)
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed.
-
4.1.6(3)(b) Stairs
(b) Stairs: Full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration....
-
4.1.6(3)(b)
If additional entrances are altered then they shall comply with 4.1.6(a); and...
-
4.1.6(3)(c)
(c) The following toilet facilities, whichever is greater: (i) At least one toilet facility for each sex in the altered building complying with 4.22, Toilet Rooms, and 4.23, Bathrooms...
-
4.1.6(3)(c)(i)
(i) If safety door edges are provided in existing automatic elevators, automatic door reopening devices may be omitted (see 4.10.6).
-
4.1.6(3)(c)(ii)
(ii) Where existing shaft configuration or technical infeasibility prohibits strict compliance with 4.10.9, the minimum car plan dimensions may be reduced by the minimum amount...
-
4.1.6(3)(c)(iii)
(iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible...
-
4.1.6(3)(d)
(d) In making the determination as to what constitutes "substantial alteration," the agency issuing standards for the facility shall consider the total cost of all alterations (including...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
4.1.6(3)(d)(ii)
(ii) If existing thresholds are 3/4 in high or less, and have (or are modified to have) a beveled edge on each side, they may remain.
-
4.1.6(3)(e)(i)
(i) Where it is technically infeasible to comply with 4.22 or 4.23, the installation of at least one unisex toilet/bathroom per floor, located in the same area as existing toilet...
-
4.1.6(3)(e)(ii)
(ii) Where it is technically infeasible to install a required standard stall (Fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e., removal of a water...
-
4.1.6(3)(e)(iii)
(iii) When existing toilet or bathing facilities are being altered and are not made accessible, signage complying with 4.30.1, 4.30.2, 4.30.3, 4.30.5, and 4.30.7 shall be provided indicating...
-
4.1.6(3)(f)(i)
(i) Where it is technically infeasible to disperse accessible seating throughout an altered assembly area, accessible seating areas may be clustered....
-
4.1.6(3)(f)(ii)
(ii) Where it is technically infeasible to alter all performing areas to be on an accessible route, at least one of each type of performing area shall be made accessible....
-
4.1.6(3)(g) Platform Lifts (Wheelchair Lifts)
(g) Platform Lifts (Wheelchair Lifts): In alterations, platform lifts (wheelchair lifts) complying with 4.11 and applicable state or local codes may be used as part of an accessible route...
-
4.1.6(3)(h) Dressing Rooms
(h) Dressing Rooms: In alterations where technical infeasibility can be demonstrated, one dressing room for each sex on each level shall be made accessible....
-
4.1.6(4)(a)
(a) Ramps. Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit...
-
4.1.6(4)(b)
Full extension of stair handrails shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration....
-
4.1.6(4)(c)
(c) Elevators. (i) If a safety door edge is provided in existing automatic elevators, then the automatic door reopening devices may be omitted (see 4.10.6). (ii) Where existing...
-
4.1.6(4)(d)
(d) Doors. (i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch...
-
4.1.6(4)(e)
Where alterations to existing facilities make strict compliance with 4.22 and 4.23 structurally impracticable, the addition of one "unisex" toilet per floor containing one water closet complying...
-
4.1.6(4)(f)
(i) In alterations where it is structurally impracticable to disperse seating throughout the assembly area, seating may be located in collected areas as structurally feasible....