(d) In making the determination as to what constitutes "substantial alteration," the agency issuing standards for the facility shall consider the total cost of all alterations (including but not limited to electrical, mechanical, plumbing, and structural changes) for a building or facility within any twelve (12) month period. For guidance in implementing this provision, an alteration to any building or facility is to be considered substantial if the total cost for this twelve month period amounts to 50 percent or more of the full and fair cash value of the building as defined in 3.5.

EXCEPTION: If the cost of the elements and spaces required by 4.1.6(3)(a), (b), or (c) exceeds 15 percent of the total cost of all other alterations, then a schedule may be established by the standard-setting and/or funding agency to provide the required improvements within a 5-year period.

EXCEPTION: Consideration shall be given to providing accessible elements and spaces in each altered building or facility complying with:

(i) 4.6, Parking and Passenger Loading Zones,

(ii) 4.15, Drinking Fountains and Water Coolers,

(iii) 4.25, Storage,

(iv) 4.28, Alarms,

(v) 4.31, Telephones,

(vi) 4.32, Seating, Tables, and Work Surfaces,

(vii) 4.33, Assembly Areas.