Using the 2010 ADA Standards for Accessible Design, the minimum bench length would be 42" and the width of the clear floor space adjacent to the end of the bench would be 30"....
Search Results "Extended Floor Surface"
-
Minimum Rear Wall Required.
-
Existing elevator cab size
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Question: Alteration vs. Maintenance for Stairs in Pre-ADA Building
The site in question is a large, pre-ADA building with retail on the ground floor and offices (not public accomodations) on the second floor....
-
Title II of the ADA
“Services, programs, and activities” also extend to child welfare hearings, custody hearings, and proceedings to terminate parental rights. 12 42 U.S.C. § 12132. 13 42 U.S.C. § 12131...
-
14. Q: May a police department wait to conduct a background check on applicants until after the information from the medical exam has been reviewed -- which is after a conditional offer of employment has been made?
bona fide" under the ADA, unless an employer has evaluated all relevant non-medical information which, from a practical and legal perspective, could reasonably have been analyzed prior to extending...
-
3.3.8 Knee Clearance Depth, minimum
* indicates data plotted in the graph ** does not include individuals with an above-knee right leg amputation (n=7) or with the right leg constrained in fully extended position...
-
3.3.7 Toe Clearance Height, minimum
* indicates data plotted in the graph ** does not include individuals with a below-knee right leg amputation (n=10) or with the right leg constrained in fully extended position...
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to...
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
§ 38.79(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
§ 38.117(b)
(b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
§ 38.99(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....