Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Extended Floor Surface"
-
11B-705.1.1.2 Dome spacing
-
Significant alternatives which minimize any significant economic impacts on small entities
analyzes the following four requirements in the proposed guidelines that will have more than minimal impacts on state and local transportation departments: Detectable warning surfaces...
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...
-
Characteristics of Study Participants
of community mobility is related to the “accessibility” of outdoor surfaces....
-
References
Standard specification for impact attenuation of surface systems under and around playground equipment. ASTM F1292‒99/04, 15.07. ...
-
Fixing the Drip: Why You Need Gutter Repair Services Near Me for Leaking Corners
The Importance of Cleaning Before Sealing You cannot seal a dirty surface. This is the golden rule of waterproofing....
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
406.2.2 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm)....
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
11B-604.8.1.1 Size
shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and 59 inches (1499 mm) deep minimum for floor...
-
11B-604.8.1.1 Size
shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and 59 inches (1499 mm) deep minimum for floor...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
Level boarding bus system
designated stops have boarding platforms and the design of boarding platforms and non-rail vehicles are coordinated to provide boarding having little or no change in level between the vehicle floor...
-
Signage (slide 11)
They really should be solid at floor level, and, not shadowed, as you [lean in to read]. Auditory signs can be an option....
-
407.8.2.1 Unobstructed Side Reach
part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...