width, 41" crossbar standard, fits 3' 8" door width, extra length crossbars available Doors: 1 3/4" thick metal or wood doors, specify if wood door Projections: 4 3/8" extended...
Search Results "Extended Floor Surface"
- Allegion Falcon 2090 Cross Bar Exit Device
- Midmark Ritter 223 Barrier-Free® Power Examination Table
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat surface,...
-
4.7.2 SLOPE
Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible route shall not exceed 1.20....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
13) Detectable warnings
Must be a textured surface on the door handle or hardware (§4.29)....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms...
-
APPENDIX A. GUIDELINES FOR SERVICE ANIMAL RELIEF AREAS (SARA)
A.4 Surfaces. A relief area should have at least two different surfaces. One should be hard and located immediately inside the entrance to allow wheelchair access....
- Wilkinson Hi-Rise Trash Chute
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
§ 38.79(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...