If accessible restrooms are not on the same floor, increase break times between sessions....
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
Best Practice Recommendations for Layout Planning
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
Built-up Curb Ramps [4.7.6]
(The surface of access aisles cannot slope more than 2% in any direction)....
-
Wheelchair Work Measurement Method
Wheelchair work per meter values for straight and turning were determined for all test course surfaces except sand, under dry conditions using the Wheelchair Work Measurement Method in accordance...
-
Fixed tactile maps
Placement on a horizontal or near horizontal surface provides the map reader with a real world orientation....
-
6.9 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
Original research for ANSI A117.1 (1957 - 1961)
Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped, ramps were assessed for flatness based on measuring 18 - inch increments on both edges of the ramped surface...
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Grade breaks are not permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks must be flush....
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M305.2.1 would require the transfer supports to be located within reach of the transfer surface and not obstruct transfer onto the surface when in position....
- Willoughby Industries ETW-1445-BS-HC Toilet for 45-degree Chase Wall
- Nova Health Products LiteRamp 6' Wheelchair and Scooter Ramp (LR6)
- Palmer Fixture iSTORM2 High Speed Hand Dryer
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Turning Space
The space may overlap the accessible route and clear floor or ground space....
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
4.30.3 Character Height
Height Above Finished Floor Minimum Character Height Suspended or Projected Overhead in compliance with 4.4.2 3 in (75mm) minimum...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.123(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....