The telephone handset shall be capable of being placed flush on the surface of the shelf....
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
11B-704.5 TTY shelf
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Trailhead Signs
signs are provided at trailheads for newly constructed or altered trails, include at minimum the following information: Trail name Length of the trail Type of surface...
-
4.3.8 Operating forces
Broader handles and larger gripping surface areas facilitate stronger grips....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
5.8.3.1 Breast Platform Height
The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
11B-608.6 Shower spray unit and water
error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of 48 inches above the finish floor...
-
E. Grab Bars
Does each accessible toilet have a horizontal grab bar on the adjacent side wall that is at least 40" long and between 33"-36" above the floor for stabilization and assistance during transfer...
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
407.12.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
218 and 810 Transportation Facilities
Detectable warnings provide a distinctively textured surface of truncated domes....
-
QUESTION: WHAT CONSTITUTES AN ALTERATION TO A PLATFORM FOR PURPOSES OF TRIGGERING THE APPLICATION OF SECTION 37.42 REQUIREMENTS?
For example, if the platform height relative to the top of rail is raised, if the old surface is removed and/or a new surface put down, or if there is a reconstruction of or structural change...
-
Scoping [4.1.2(1), 4.1.3(1)] and Location [4.3.2]
Clear width, surface texture, running and cross slope, and the treatment of changes in level help determine the usability of walking surfaces by people with mobility impairments....
-
1016.5 Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on outdoor recreation access routes can be obstacles....