For instance, when this project began, tolerances for the measurement of the slope, flatness, and smoothness of exterior walking and rolling surfaces in concrete, asphalt, unit masonry,...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
Purpose of the project
-
§ 38.159(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches (32 mm) and 11/2 inches (38 mm) or shall provide an equivalent grasping surface, and have eased edges with corner radii...
-
§ 38.29(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)
entrance to the voting area contains a counter and two drinking fountains that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor...
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3)....
-
R304.5.1.2 Shared Use Paths
The AASHTO Guide recommends that where curb ramps are provided on shared use paths, the curb ramps should extend the full width of the path, not including any flared sides....
- Cybex Total Access Row/Rear Delt Exercise Machine
- Panda S.15 All Wood with Aluminum Core Lift & Slide System
- Panda S.12 Solid Wood Lift & Slide System
- Panda S.11 Aluminum/Wood Clad Lift & Slide System
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
1007.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the specific story, floor...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. [ECTCR UFAS 4.25.3, Fig. 38]...
-
G. Self-serve Items
If a counter is used for serving breakfast or other food products, does it have at least a 36" long section that is no higher than 36" above the floor to allow persons who use wheelchairs...
-
1(3)(a)(ii)
(ii) If the building elevator is provided as a means of access to dwelling units other than dwelling units on a ground floor, then the building is an elevator building which is a covered...
-
211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211....
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat, or manual switch mounted on or near the door itself (see power-assisted door)....
-
7.2 SERVICE COUNTERS
distribution of goods to the public, an auxiliary counter or a portion of the main counter shall be provided with a maximum height of between 28 in to 34 in (710 mm to 865 mm) above the floor...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
233 Residential Facilities
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
Background
This is especially the case with issues related to surfaces....
-
1011.4.2 Wheelchair Space
Picnic tables shall provide at least one wheelchair space for each 24 linear feet (7320 mm) of usable table surface perimeter. ...
-
704.5 TTY Shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...