objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
Search Results "Extended Floor Surface"
-
11B-307.3 Post-mounted objects
-
Is Identification of Which Means of Egress Are Available/Closest Necessary?
Simple floor plans of the building indicating the location of and routes to usable circulation paths should be available in alternative formats such as single-line, high-contrast plans....
-
4.1.2(7)
EXCEPTION: In multiple-story buildings and facilities where at-grade egress from each floor is impossible, either of the following is permitted: the provision within each story of approved...
-
11B-307.3 Post-mounted objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
-
11B-307.3 Post-mounted objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
-
106.5.60 Shopping Center or Shopping Mall
The facility housing a "shopping center or shopping mall" only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by...
-
404.2.11 Vision Lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum above the finish floor...
-
307.3 Post-Mounted Objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor...
-
Shopping Center or Shopping Mall
The facility housing a “shopping center or shopping mall” only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by...
-
Location
Location of Swing Away Grab Bars (Linido grab bars pictured here) Rear-mounted (either floor or wall), swing away (or fold up) grab bars (e.g., Linido or Bobrick) on both sides of...
-
III-1.7000 Relationship to title II
The first floor is leased as commercial space to a restaurant, a newsstand, and a travel agency....
-
1134A.8, Item 8
Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor....
-
§382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
Feature 5 - Meeting Space
Feature 5 - Meeting Space The meeting space must have an accessible floor plan. ...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. [ECTCR UFAS 5.2]...
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
§ 1194.25(j)(2)
(2) Where any operable control is 10 inches or less behind the reference plane, the height shall be 54 inches maximum and 15 inches minimum above the floor....
-
Question 16
., listening stations for recordings, try-out areas for electronics) clear of obstacles that block floor or knee clearance?...
-
Toilets
Provide a toilet seat that is 17" to 19" above the finished floor in the north women's toilet room located in the "Celebrity Spies" exhibit area. See Standards § 4.16.3....
-
5.8.2.1 Height of Breast Platform At Time of Measurement
All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
§27.71(k)(7)(i) Visibility.
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....