At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
Search Results "Horizontal Projection"
Commonly Searched Documents
-
11B-505.10.2 Top extension at stairs
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
7. Grab Bars
Are there two horizontal grab bars (one high/one low) along the side of the tub that are at least 24" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat -...
-
1.1.11 Ramp running slope
Measure for overall running slope of ramps by determining elevations at the top and bottom of the ramp at the midpoint of the width of each ramp run and calculate the slope using the horizontal...
-
Back Support
rule required back support to be provided that extends vertically from a point no more than 2 inches above the bench to a height of at least 18 inches above the bench and that extends horizontally...
-
BACKGROUND
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302 Description: Transfer supports and their connections must be capable of resisting sufficient vertical and horizontal...
-
Water Flow: ADA Standard Section 602.6
Section 602.6 covers the current ADA Standards for the drinking fountain water flow.
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
Appendix C: Resources
Project UNIFY www.specialolympics.org/projectunify.aspx The Special Olympics' Project UNIFY is supported by the Office of Special Education Programs (OSEP)....
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum....
-
UNREASONABLE HARDSHIP
When the enforcing agency finds that compliance with the building standard would make the specific work of the project affected by the building standard infeasible, based on an overall evaluation...
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm) minimum....
-
UNREASONABLE HARDSHIP
When the enforcing agency finds that compliance with the building standard would make the specific work of the project affected by the building standard infeasible, based on an overall evaluation...
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-202 Existing buildings and facilities
of this code as those requirements or regulations now exist or are hereafter amended consisting of one or more of the following items shall be limited to the actual scope of work of the project...
-
Many properties do NOT have enough electricity available to support significant charging installations, so for now, utilities and others are doing “make ready” spaces (upgrading the supporting infrastructure in a parking space for future use without adding the actual charger). How would make ready spaces comply with the ADA standards? Additionally, consider a site with 10 make ready spaces. Would the standards apply differently if that site has no chargers presently installed versus having one active charger installed?
If the entire project consists of 10 vehicle spaces with the infrastructure installed, but without chargers, then CBC Chapter 11B accessibility provisions do not apply....
-
§8.23(b)(1)
(1) Subject to paragraph (b)(2) of this section, alterations to dwelling units in a multifamily housing project (including public housing) shall, to the maximum extent feasible, be made...
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
The horizontal distance from the transfer surface should be no more than 3 inches from the edge of the patient support surface....