automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required as part of the accessible means of egress on floors provided with a horizontal...
Search Results "Horizontal Projection"
-
1009.2.1 Elevators required
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
1009.4.2 Area of refuge
Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit....
-
1009.3.3 Area of Refuge
Areas of refuge are not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
- SCI Empowerment Project by University of Washington Department of Rehabilitation Medicine
-
TRANSIT BOARDING PLATFORM
[DSA-AC] A horizontal, generally level surface, whether raised above, recessed below or level with a transit rail, from which persons embark/disembark a fixed rail vehicle....
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Stair widths
However, 1014.8 discusses projections and allows projections into the required width of stairs up to 4 1/2" at or below the handrail height....
-
Character Height: ADA Standard Section 703.5.5
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
R408.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
T304.3 Location
provided at a wheelchair space shall be located adjacent to the wheelchair space 24 inches (610 mm) minimum and 36 inches (915 mm) maximum from the rear of the wheelchair space measured horizontally...
-
H27
Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor?...
-
e-ii
[ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for 12 inches of horizontal distance....
-
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Public Building
(v) On or used in connection with river, harbor, flood control, reclamation or power projects, or for chemical manufacturing or development projects, or for nuclear production, research,...
-
Knee and Toe Clearance (M303.2.4)
The Wheeled Mobility Anthropometry Project showed that these dimensions do not accommodate many people in the sample and recommended alternative dimensions that would accommodate 95 percent...
-
Issue 22: How is accessibility for persons with low vision assessed during the design review process?
[If] that person doesn’t give [the regional officer] the project to review, or [doesn’t] tell [the regional officers] this project needs review, then [the regional officer doesn’t] review...
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
Dislife: More than a sign
Requires the Registered User plan or above. Login!
-
2e
Is there a horizontal grab bar along each of the three shower walls at 33"-36" above the floor as shown in Figure 37(b) below?...
-
5. Grab Bar
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and aid in transfer from a wheelchair to the folding shower seat?...
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...