Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
Search Results "Horizontal Projection"
Commonly Searched Documents
-
11B-405.9 Edge protection
-
1009.3.3 Area of Refuge
Areas of refuge are not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
-
Issue 22: How is accessibility for persons with low vision assessed during the design review process?
[If] that person doesn’t give [the regional officer] the project to review, or [doesn’t] tell [the regional officers] this project needs review, then [the regional officer doesn’t] review...
-
Character Height: ADA Standard Section 703.5.5
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
5b. Ramp Slope
[ADA Stds 4.7.2] Note: 1:12 is one inch of vertical height for 12 inches of horizontal distance. Yes _____ No _____...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
- SCI Empowerment Project by University of Washington Department of Rehabilitation Medicine
-
1132A.9 Smooth surface
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other and be free of sharp or abrasive edges....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal...
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
TRANSIT BOARDING PLATFORM
[DSA-AC] A horizontal, generally level surface, whether raised above, recessed below or level with a transit rail, from which persons embark/disembark a fixed rail vehicle....
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
UNREASONABLE HARDSHIP
When the enforcing agency finds that compliance with the building standard would make the specific work of the project affected by the building standard infeasible, based on an overall evaluation...
-
Cost Estimates for Barrier Removal
They are adjusted for each project according to the factors below and appear in the possible solution pages for that project as adjusted....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
§8.22(b)
(b) Subject to paragraph (c) of this section, a minimum of five percent of the total dwelling units or at least one unit in a multifamily housing project, whichever is greater, shall be...