The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
Search Results "Signage Height"
Commonly Searched Documents
-
11B-604.4 Seats
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: 1....
-
Signage
Comment and Question by Tom Williams: Along with the discussion about wayfinding and signage, it brings out the issue of contrast and tactile signs and so on....
-
4.1.6(1)(h) Entrances
If a particular entrance is not made accessible, appropriate accessible signage indicating the location of the nearest accessible entrance(s) shall be installed at or near the inaccessible...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
17 Inch Low Height
17 Inch Low Height A portion of the Committee maintained that a height range of 17 inches - 25 inches would accommodate a significant portion of people with disabilities....
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor. Provide a clearance of at least 29 in (735 mm) from the floor to...
-
Circulation and flow
There is no signage to the interior accessible route between the Museum lobby and the Spy City Café. See Standards § 4.1.2(7)(c). b....
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
11B-216.5.2 Parking facilities
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the...
-
4.1.3(16)(b)
(b) Other signs which provide direction to or information about functional spaces of the building shall comply with 4.30.1, 4.30.2, 4.30.3, and 4.30.5. EXCEPTION: Building...
-
11B-216.5.2 Parking facilities
Signs within parking facilities shall comply with Section 11B-216.5.2.
-
11B-216.5.2.1 Signs intended for use by pedestrians
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the...
-
11B-216.5.2.1 Signs intended for use by pedestrians
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the...
-
11B-216.5.2 Parking facilities
Signs within parking facilities shall comply with Section 11B-216.5.2.
-
Entrances: ADA Standard Section 216.6
Section 216.6 covers scoping requirements in the current ADA Standards for signs at entrances.
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.