over rough or uneven surfaces, using toilet and bathing facilities, reaching and seeing items placed at conventional heights, and negotiating steps or changes in level at the entrance/exit...
Search Results "Ground Floor Exit"
-
Mobility
-
D) Curb Ramps at Intersections
This type of curb ramp has flared sides and must be used when pedestrians may enter or exit the curb ramp from the side....
-
ADA Checklist for Existing Facilities
Copyright © 2017 ADA Checklist for Exiting Facilities. You can freely reproduce and distribute this content. Include proper attribution....
-
SUMMARY AND CONCLUSIONS
When traffic signals are installed that stop both entry and exit traffic at the same time while pedestrians cross both directions of traffic, queues back up into the circulating roadway...
-
ASME A18.1 Safety Standard [§410.1]
Under the ADA Standards, platform lifts must be independently operable and must allow unassisted entry and exit from the lift....
-
11B-410.1 General
Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. [2010 ADAS] Advisory 410.1 General....
-
11B-410.1 General
Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. Advisory 11B-410.1 General....
-
Standing Supports (M304.3 and M305.3)
edge on the single entry ramp allows for enough coverage in length to assist the patient for stability to grab on both sides, to gain access to the platform for this one way entry and exit...
-
ASME
The provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches...
-
Ask Questions and Provide Instructions
If you are receiving assistance with transportation between gates by ground wheelchair, remember to instruct the personnel assisting you on your specific needs, e.g., whether or not you...
-
Summary: What Every Playground Owner Should Know About the Accessibility of Their Playground Surfaces
Playground owners, designers and maintenance personnel must have a good understanding of the requirements for ground level accessible routes within the play area. ...
- Cybex Total Access Row/Rear Delt Exercise Machine
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
T404.3 Ramps and Bridgeplates
Where the space between the floor of non-rail vehicles and a boarding platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger...
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
G. Compartment Size
If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs...
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(3) If a medicine cabinet is provided above the lavatory, then the bottom of the medicine cabinet shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor....
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
(1)(d)
Controls for flush valves should be mounted no more than 44 inches (1120 mm) above the floor....
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...