grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
Search Results "Ground Floor Exit"
-
§ 38.123(a)(3)
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
When is accessibility required for a live work conversion project?
Background The building is a 2-story concrete structure with 37,690 sf on the first floor and 22,334 sf on the second floor The building’s freight elevator has been vacated/removed...
- Rebuilding Together Of the Triangle - Raleigh, NC
- Panda S.85 All Aluminum Slim Profile Lift and Slide System
- Guldmann Basic High Sling - Kids
-
Industry Standards
621-94 (1999)e1 Standard Practice for the Use of Metric (SI) Units in Building Design and Construction ASTM E 1155-96 (2001) Standard Test Method for Determining FF Floor...
-
3. Lift Compatibility Exception
One commenter, a manufacturer, agreed that equipment designed for use with an overhead lift should be excepted, and also stated that portable floor lifts should be designed to be compatible...
-
1134A.6 Showers
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
Meeting Purpose
disabilities (such as mobility, breathing, allergies, hearing, seeing, understanding or chronic conditions) and may have difficulty or be unable to: use stairwells, hear alarms, see or read exit...
-
III-4.2100 General
The clinic occupies several floors of a multistory building. During an emergency, elevators, which are the normal means of exiting from the clinic, will be shut off....
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
M301.4 Lift Compatibility
, diagnostic equipment shall not be required to meet the lift compatibility requirements of this section provided that such equipment is clearly labeled as not compatible with portable floor...
-
M302.4 Lift Compatibility
, diagnostic equipment shall not be required to meet the lift compatibility requirements of this section provided that such equipment is clearly labeled as not compatible with portable floor...
-
Basic Features
Careful planning and design will incorporate elements such as a wider entrance door, adequate clear floor space, appropriate placement and models of fixtures and furniture, and grab bars...
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
deep, from the initially proposed 25 inch absolute dimension; increasing the knee clearance directly underneath the breast platform to a minimum of 18 inches; and assuring unobstructed floor...
-
4.21.3 SEAT
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. The seat shall be on the wall opposite the controls....
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Floor electrical receptacles are also exempt. Communication receptacles serving a dedicated use include phone jacks, data ports, network and audio-visual connections....
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....