Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
Search Results "Compartment Width"
Commonly Searched Documents
-
D2
-
3. Measuring Door Openings
This measures the clear width of the door opening through which people pass, which is less than the width of the door itself....
-
Size and Arrangement [4.17.3]
[See subsections ...]
-
Bathrooms
Bathrooms An accessible bathroom can be equipped with either a tub or shower (transfer or roll-in).
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
A7
Is the width of the curb ramp surface at least 36 inches (not counting the side flares)? [ADA Standards § 4.7.3] Yes No...
-
502.3.1 Width
502.3.1 Width. Access aisles serving car and van parking spaces shall be 60 inches (1525 mm) wide minimum....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-502.7.2 Wheel stops
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
2. Libraries
2. Libraries 144. Kirola testified to having used three of the City's twenty-eight libraries: the Main Library, the Western Addition Branch Library, and the Parkside Branch...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
7a.
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
g-i
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No...
-
3. Doors
Doors with 32 inches of clear opening width (when a sliding door is fully opened or a hinged door is open 90 degrees). Clear floor space is required in front of the door....
-
604.8.1.7 Water closet
In new construction, the accessible water closet within the wheelchair accessible compartment shall be located in the corner, diagonal to the door....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
, in the 2008 Draft Revised Guidelines, the Access Board modified the proposed requirements for maneuvering clearances and clear width of circulation paths....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
1134A.6 Showers
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall. 4. ...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions