Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
Search Results "Compartment Width"
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
-
3.3.10 90-Degree Turn
The width required for all participants to complete a 90-degree turn in our sample was much smaller than the UDI findings (Figure 3‒10), due to differences in the abilities of people or/...
-
H. Stall Door
H. If the accessible toilet is in a stall, is the stall door positioned diagonally opposite, not directly in front of, the toilet so persons who use wheelchairs may pull fully into...
-
4.17.1 Location
Accessible toilet stalls shall be on an accessible route and shall meet the requirements of 4.17.
-
4.17.1 LOCATION
Accessible toilet stalls shall be on an accessible route and shall meet the requirements of 4.17.
-
404.3.1 Clear Width
404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
11B-403.5.1 Clear width
The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that...
-
11B-403.5.1 Clear width
Exceptions: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated...
-
§ 38.113(a) Clear width
(a) Clear width....
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General....
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General....
-
11B-403.5.1 Clear width
The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that...
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General....
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. [2010 ADAS] Advisory 608.1 General. ...
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. Advisory 11B-608.1 General....
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. [2010 ADAS] Advisory 608.1 General....
-
Seat width and depth
Seat width and depth: ADA-ABA currently requires a minimum entry point of 24 inches for transfer steps in play (Section 1008.3.1.1) [7] and pool areas (Section 1009.4.5) [7]. ...
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
Clearances [§403.5]
Clearances [§403.5] The minimum 36” continuous clear width of accessible routes can reduce to 32” at points, such as doorways, for a maximum distance of 24”....
-
End-of-Row Stalls
End-of-Row Stalls The design of end-of-row stalls incorporates aisle space into the stall for easier maneuvering; consider this design even where a stall is not located at the...
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....