At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum. Exceptions: 1....
Search Results "Compartment Width"
Commonly Searched Documents
-
11B-1008.2.4.1 Ground level
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project more...
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1. ...
-
Turning Space [§304]
Clear Width at 180 Degree Turn Around a Narrow Obstruction Recommendation: Turning space is recommended in small spaces with entrapment risks as well as at dead-end aisles...
- Figure 604.8.2 Ambulatory Accessible Toilet Compartment – Drawing from the U.S. Access Board
-
Wheelchair Space Overlap in Assembly Areas
4.33.3 of the 1991 Standards and the 2010 Standards, at sections 402, 403.5.1, 802.1.4, and 802.1.5, require walkways that are part of an accessible route to have a 36-inch minimum clear width...
-
Clear Tread Width [1017.3]
The clear tread width of trails must be a minimum of 36 inches (figure 2)....
-
Surface and Clear Tread Width on Beach Access Routes
A beach access route must have a firm, stable surface, and have a clear tread width of 60 inches (1,525 millimeters) minimum....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
- Weizel Security 826-S74 SR™ Partition Door
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
1134A.6, Item 1
1. Size. When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following requirements.
-
11B-213.3.6 Bathing facilities
Where bathtubs or showers are provided, at least one bathtub complying with Section 11B-607 or at least one shower complying with Section 11B-608 shall be provided. Where two or more...
-
1134A.6 Showers
1134A.6 Showers. Showers required to be accessible shall comply with this section.
-
F213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.
-
213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.
-
K. Ambulatory Stall
K. If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor...
-
213.3.6 Bathing Facilities
213.3.6 Bathing Facilities. Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.