Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
Search Results "Clear Floor Area"
-
408.4.1 Car Dimensions and Doors
-
407.12.3.2.2 Knee and Toe Space
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of obstructions....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADA Standards] 904.4.2 Forward Approach....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
Protrusions
Protrusions There may be some protrusions into wheelchair spaces on rides, but not into circulation areas, accessible routes,or load and unload areas....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than twenty-five beds covered by this section, a minimum of five percent (5%) of the beds shall have clear floor space complying with section 806.2.3....
-
§ 35.151(e)(1)
(1) In sleeping rooms covered by this section with more than twenty-five beds, five percent (5%) minimum of the beds shall have clear floor space complying with section 806.2.3....
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not obstructed...
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
9.5.1 New Construction
In new construction all public use and common use areas are required to be designed and constructed to comply with section 4....
-
4.34.6.4(3)
(3) Counter thickness and supporting structure shall be 2 in (50 mm) maximum over the required clear area....
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
Swing bays that provide an accessible route, clear floor or ground space, maneuvering space, and the seat at a height between 11 to 24 inches to more than one swing, can count each swing...
-
Pay Stations
Require-ments [sic] for operable parts cover clear floor space, operating characteristics, and location within accessible reach ranges....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
Solutions for Accessibility: Problems Involving the Parking Area
[See subsections ...]
-
Solutions for Accessibility: Problems Involving Voting Area
[See subsections ...]
-
A4.29.3 TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Tactile signals for hand reception are useful if it is certain that the signals will be touched.
-
11B-809.5.6 Site, building, or floor entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall...