22. How can I get copies of the ASTM standards that apply to play areas?
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
§382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§27.71(k)(7)(i) Visibility.
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 27.71(k)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
5.1.9 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
PATH OF TRAVEL
area with an exterior approach (including sidewalks, streets, and parking areas), an entrance to the facility, and other parts of the facility....
-
Definition of "Mezzanine"
"Mezzanine" is now defined by the same definition used in the IBC: "An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than...
-
5.8.2.7 Base Support Allowance
Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½ inches high....
-
Why is book writing useful for building personal or professional credibility?
It allows people to share their knowledge, skills, experiences, and ideas in a clear and organized manner....
-
2. Typical Issues for People Who are Blind or Have Low Vision
That means any area where people using the shelter can walk, including hallways, corridors, eating areas, and sleeping areas, must be free of objects that cannot be detected by a person...
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
§ 35.151(e)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
11B-106.5 Defined terms
OF REFUGE AREA OF SPORT ACTIVITY ASSEMBLY AREA ASSISTIVE LISTENING SYSTEM (ALS) AUTOMATIC DOOR AUTOMATIC TELLER MACHINE (ATM) BATHROOM BLENDED TRANSITION BOARDING...
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Height and Clearances [4.19.2]
Only a portion of the usable clear floor space can "count" as toe space, which is why a maximum depth and minimum height are specified for the front of the underlap of the required clear...
-
R308.2 Transit Shelters
Transit shelters shall be connected by pedestrian access routes complying with R302 to boarding and alighting areas or boarding platforms complying with R308.1....