shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
Search Results "Floor Slope"
-
604.8.1.1 Size
-
Shower Compartments
inch maximum curb in transfer-type showers in alterations to existing facilities, where recessing the compartment to achieve a ½-inch curb will disturb the structural reinforcement of the floor...
-
M301.4 Lift Compatibility
M01.4.1 Clearance in Base Proposed requirement: The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor...
-
Display Screens
suggested that we change the requirement for display screens such that they must not only be visible, but also readable, from a point located 40 inches (1015 mm) above the center of the clear floor...
-
4.1.3(5)*
For example, floors above or below the accessible ground floor must meet the requirements of this section except for elevator service....
-
Transfer Heights
that the majority of WMDs (92% of subjects in the first phase and the 5th percentile (or approximately 94% in this study) could transfer within one inch of the mean wheelchair seat to floor...
-
BS8300:2001 Research
They include information on space required for “kneeholes,” reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....
-
A. Arena Assembly Seating:
The floor surface of the companion seat shall be at the same elevation as the floor surface of the wheelchair space....
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
- Elkay Cane Apron LKAPR1 for use with SwirlFlo® Bi-level Drinking Fountains
- Access-Able Designs Shower Transfer Bench SH-420-2SDL
- Kohler San Tropez® Vertical Spray Bidet with 4 Faucet Holes
- Florestone 35-62H Barrier-Free Shower
- Federal Elevator Carelift Wheelchair Lift
- Waterless Co. Urinal Borrego 2103
- Collapsible Water Retainer Shower Dam for Shower Threshold
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY. ...
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
3. Lavatory knee clearance
faucet hardware, the following features need to be provided -- a 29-inch-high clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor...
-
707 Automatic Teller Machines and Fare Machines
Requirements address clear floor or ground space (707.2), operable parts (707.3), privacy (707.4), speech output (707.5), input (707.6), display screens (707.7), and braille instructions...