One or two shelves can be vertically adjusted in their steel channels to provide needed space between shelves and appropriate hanging distance to the floor....
Search Results "Floor Slope"
- Magnuson Group WH Hanger Style Wall Rack
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
- Bradley Aerix+ High Speed Vertical Dual-Sided Hand Dryer
-
Salsbury Industries Designer Wood Locker
Requires the Registered User plan or above. Login!
- Cybex Total Access Cable Column Exercise Machine
- Nana Wall Systems, Inc. High Velocity Hurricane Zone Folding Glass Walls SL73
- Allegion Von Duprin 55 Series Cross Bar Exit Devices
- Garaventa Artira Inclined Platform Wheelchair Lift
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
Weight Scales
Unit costs are presented for wheelchair scales with raised platforms and with flush platforms in the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
Openings, Width and Length of Wheelchair Space
Wheelchair spaces must have a clear width of 30 inches minimum and a clear length of 48 inches minimum, measured to at least 9 inches above the floor surface....
-
D. Signage
will be relocated to between 48 inches measured to the baseline of the lowest tactile character and 60 inches measured to the baseline of the highest tactile character above the finish floor...
-
Adaptability
Rooms need to be designed to provide required clear floor space at fixtures, turning space, and door clearance....
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project more...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
abilities of power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...
-
4.1.2(8)
(8) At least one principal entrance at each grade floor level to a building or facility shall comply with 4.14, Entrances....
-
1014.1 General
The technical requirements address the entrance to camp shelters (1014.2), including transfer access (1014.2.1) and roll-in access (1014.2.2); and the floor within camp shelters (1014.3)...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...