A level from 10 to 30 footcandles is recommended uniformly over the sign surface....
Search Results "Fire-Building Surface"
-
Illumination Levels (Reserved) [4.30.8]
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches 430 to 485 mm) above the load and unload surface....
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
Boat Slips: ADA Standard Section 1003.2.1
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
101.1.2
101.1.2 All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation, and commercial facilities subject to this code shall comply...
-
206.4.2 Parking Structure Entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with 404...
-
4.1.3(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
4.1.3(8)(b)(i)
(i) In addition, if direct access is provided for pedestrians from an enclosed parking garage to the building, at least one direct entrance from the garage to the building must be accessible...
-
4.1.2(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
11B-206.2.1 Site arrival points
provided within the site from accessible parking spaces and accessible drop-off and passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible building...
-
§104.23(c)(1)
(1) Effective as of January 18, 1991, design, construction, or alteration of buildings in conformance with sections 3-8 of the Uniform Federal Accessibility Standards (UFAS) (Appendix A...
-
4.6.2 Location
Accessible parking spaces serving a particular building shall be located on the shortest accessible route of travel from adjacent parking to an accessible entrance....
-
4.1.4(13) UTILITY AND MISCELLANEOUS
Utility and miscellaneous occupancies include, among others, accessory buildings and structures, such as: Facilities Fences over 6 ft. high Tanks Cooling towers Retaining...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway. ...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-705.1.1.3.2
Detectable warning surfaces shall provide a 70 percent minimum visual contrast with adjacent walking surfaces....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
4. Do the carpet requirements of Section 302.2 apply to ground level accessible routes within a play area?
Accessible playground surfaces, including turf-like surfaces, must meet the requirements of ASTM F 1951-99....
-
5.4.1.1 Transfer Support Location Recommendation for Stretchers
5.4.1.1 Transfer Support Location Recommendation for Stretchers For Stretchers, the transfer surface is oriented along the long side of the surface....
-
4.5.3* CARPET
If carpet or carpet tile is used on a ground or floor surface, then it shall be securely attached; have a firm cushion, pad, or backing or no cushion or pad; and have a level loop, textured...
-
Data Analyses
Data Analyses Net energy consumption – the additional energy utilized during walking in excess of resting levels – was calculated for each surface....